Protection of transmission lines pdf

Consider a case of a radial line supplying three substation as shown in fig. Proposed work has made an attempt to find solution to the problem of fault detection and location by relay using post fault high frequency signals. Transmission lines are a vital part of the electrical distribution system, as they provide the path to transfer power between generation and load. Distance protection settings for two ended transmission lines. Modern microprocessorbased line current differential relays can provide at least one zone of distance protection.

The complexity of protecting threeterminal transmission lines. There are several methods available for the protection of transmission and distribution lines 69. Transmission lines a transmission line connects a generator to a load a two port network transmission lines include physical construction. Aug 31, 2018 protection of lines or feeder august 31, 2018 february 24, 2012 by electrical4u as the length of electrical power transmission line is generally long enough and it runs through open atmosphere, the probability of occurring fault in electrical power transmission line is much higher than that of electrical power transformers and alternators. Protection of transmission lines is performed using distance relays. The type of conductor, the size of conductor, and spacing of conductors determines the impedance of the line, and the physical response to short circuit conditions, as well as line charging current. Current differential line protection current differential relaying is a method of extending the benefits of differential protection as applied to transformers, buses or generators to the protection of transmission lines. Environmental protection guidelines for transmission lines. Distribution linenormally considered to be a line that carries electricity at lower.

Protection of transmission lines standard tasnetworks. Also, the amount of attenuation is extremely small, since this is due to ro. Computer models of towers, ground wires and conductors. Transmission plans are often evaluated in forward looking ten year plans, and are refined as circumstances change. Transmission system is a system which between the generation and the distribution centers.

Typically, distance relays protect transmission lines from power system faults by using the method of step distance protection. Transmission line vs distribution line transmission line normally carries electricity at voltages of 69 kv or greater and is used to transmit electric power over relatively long distances, usually from a central generating station to main substations. Protection of transmission lines distance protection by, rohini haridas assistant professor, dept of electrical engineering, ssgm college of engineering,shegaon 2. Computer models of towers, ground wires and conductors, and the earthing system are presented. Protection scheme0protection scheme for transmission lines as per cbip guidelines should have two independent high speed main protectionschemes two stage over voltage protection sensitive idmt directional ef relays auto reclose relay suitable for 1 ph3ph with deadlinecharging and synchro check reclosure.

Assume we have a transmission line in which air separated the two perfect conductors. Zone 3 is the backup protection for all the lines connected to the remote end bus. However, any relay tester can perform successful endtoend tests with a basic a basic understanding of transmission line protection or 21. Lightning protection of transmission lines with polymerhoused surge arresters m. Current differential line protection setting consideration. Hence backup relay is slower in action than primary relay. Overload or overcurrent protection owes its application to the fact that the fault current in the event of a short circuit will raise to a. An introduction to electric power transmission table of content toc glossary about transmission lines electricity generation and delivery transmission line ownership and funding anatomy of a transmission line buildingmaintaining transmission lines planning the system permitting potential environmental impacts. An introduction to electric power transmission presentation. Provisions will be made to deenergize only those buses and circuits necessary to accomplish the work. The microwave channels are used for all types of protections otherwise based on power line carrier or pilotwire. Model setting calculations for typical ieds line protection.

This document gives the model setting calculations, line protection setting guide lines, protection system audit check lists, recommendations for protection system management and some details connected with protection audit. Transmission lines operate at voltage levels from 69kv to 765kv, and are ideally tightly interconnected for reliable operation. Introduction transmission lines are a vital part of the electrical distribution system, as they provide the path to transfer power between generation and load. Microwave channel protection of transmission lines. The protection system includes a direct current, dc, bus, a device configured to connect an hvdc transmission line to the bus, at least one dc circuit breaker arranged for disconnecting the transmission line from the bus upon reception of a trip signal, current and voltage sensors, an inductor arranged. Transmission line relay loadability sequential clearing for transmission line faults. Types of electrical protection relays or protective relays. Fundamental overcurrent, distance and differential. Many transmission lines are protected by two protection systems. These relays are dependent on knowing the zero sequence impedance of the transmission line it shall protect in order to be set correctly. Electrical power system by jb gupta is very useful for basics ideas of power system and best for competitive exams and topics are covered in sufficient details. Dispersionless transmission lines because lo and co do not depend on frequency for a superconductor, the phase velocity is independent of frequency. Three zone protection by using distance relays in simulink. So that a pulse will propagate down a superconducting transmission line without dispersing.

One of the protection relays used in power system is distance or impedance relay which is mainly used in transmission system these relays can be used as primary or backup protection. Lightning protection of compact transmission lines. It typically takes longer to develop, permit and construct a transmission line than it does to develop a generation facility. This paper examines the outage rate caused by lightning strokes on compact transmission lines tl. Mainly intended to cover the entire length of the protected line length and set to operate instantaneously i. Distance protection relay is widely spread employed for the protection of highvoltage ac transmission line and distribution lines. Assuming ex,t 2cos3x1015t 107x vm, calculate the wave velocity. This paper describes different cases of parallel transmission lines and analyzes some well known application problems associated with their protection. Introduction and need to discuss backup protection backup protection can, and in many cases does, play a significant role in providing adequate system performance or aiding in containing. Pdf three zone distance protection of transmission line. Distance protection algorithm for three terminal transmission lines using.

Manual for transmission lines and substation construction. Lightning protection of transmission lines with polymer. The tower top transient voltage, following a lightning stroke is determined using the emtpatp program. In the event of a discrepancy between this guide and any act or regulation, the act or regulation prevails. Westerns substations and transmission lines are under the jurisdiction of westerns power operation and maintenance staff and are subject to their standard operating procedures and regulations. While guide lines as finalized by the subcommittee have been used for the setting calculation document on transmission lines, for other power system elements like transformer, shunt reactor and bus bar, guide lines as given in cbip documents and manufacturers manuals have been used. Then according to history and progress of the technology, transmission lines mostly use three phase alternating current ac. The physical construction of the transmission line is also a factor in protection system application. Information on the concepts of protection of ac transmission lines is presented in this guide. Included frequency protection in transmission line relays. However, protection of threeterminal lines presents serious challenges and requires very careful design and application to maintain overall system reliability the protection challenges presented by threeterminal lines include the following. Comparing current flowing into a line to the current flowing out of the same line allows for a simple protection scheme.

Transmission and distribution lines protection transmission lines are exposed to short circuits between phases or from phase to ground. This is the simplest way of protecting a line and is, therefore, widely used. Time graded protection is a scheme of over current protection, in which the discrimination is incorporated i. Power transmission line protection systems is one of the most important system under electrical power system. Primary relay or primary protection relay is the first line of power system protection whereas backup relay is operated only when primary relay fails to be operated during a fault. Based on application the protection relay can be categorized asprimary relay. We represent as a large number of small inductors and capacitors spaced. Rockefeller first presented the implementation of digital relaying in 1969 2. Ieee guide for protective relay applications to transmission. Protection of parallel double circuit transmission lines in.

Compact and conventional transmission lines are different in terms of design and structure. Pdf advanced transmission line protection system researchgate. During fault, the only circuit breaker closest to the fault point should be tripped. Protection of line should have some special features, such as. Provisions will be made to deenergize only those buses. Provide basic understanding of protection and controls for transmission substations provide guidance on specifying protective relaying provide guidance on executing protection and control scope. The implementation of distance relays requires understanding of its operating principles. To obtain an adequate measurement variable for the protective device, the. Effect of lightning on transmission lines the frequency with which lightning will strike a transmission line depends on a number of factors. Us20088802a1 fault protection of hvdc transmission lines.

To avoid the loss of discrimination with the zone 1 protection of the following line section, zone i distance is set at 80 to 90 % of the line and not 100%. Ieee guide for protective relay applications to transmission lines. Jul 03, 2014 endtoend testing can appear to be a daunting task. Hon tat hui transmission lines basic theories nusece ee2011 28 example 1 a 100. Pdf this is a new technique for the protection of transmission systems by using the global positioning system gps and fault generated transients. The transmission is generally by line of sight and this must take into account the curvature of earth and topology of the route cover which the transmission takes place. Three zone protection by using distance relays in simulinkmatlab. This produces the conventional mho characteristic of fig.

Two parallel wires coaxial cable microstrip line optical fiber waveguide very high frequencies, very low loss, expensive etc. Environmental protection guidelines for transmission lines general this guideline replaces conservation and information letter 952 and the 1994 guide for transmission lines. The multiplegaparresterconsists of a number of knurled cylindersplaced onan insulated base. Applications of the concepts to accepted transmission line protection schemes are also presented. This best management practice bmp manual and field guide were created in. Distance protection performance problems are in the focus due to the fact that they are the most commonly used protection type for parallel transmission.

Apr 25, 2012 protection scheme0protection scheme for transmission lines as per cbip guidelines should have two independent high speed main protectionschemes two stage over voltage protection sensitive idmt directional ef relays auto reclose relay suitable for 1 ph3ph with deadlinecharging and synchro check reclosure. The dc resistance of a conductor is expressed in terms of. If the circuit breaker closest to the faulty point, fails to trip, the circuit breaker just next to this breaker will trip as back up. Features include a fourshot recloser, patented capacitance voltage transformer cvt transient overreach logic to enhance security of zone 1 distance elements, and overcurrent elements with directional control, monitoring, and metering. Construction of transmission and distribution lines. These values determine the powercarrying capacity of the transmission line and the voltage drop across it at full load.

The aim of this this technical article is to cover the most important principles of four fundamental relay protections. Pdf digital distance protection of transmission lines in the. Protection systems are deemed to be redundant when both protection systems operate independently and do not share any components. In adra, a morphological fault detector mfd designed based on mm is used to determine the occurrence of a fault. Ensure adequate transmission from resources to serve loads in a reliable and economical manner. Protection of transmission line using gps authorstream. Determination of the lightning performance of compact transmission lines is described. Pdf distance protection algorithm for three terminal. Best practices for protection and control applications for transmission substations. The range of the possible fault current, the effect of load, the question of directionality and the impact of system configuration are all part of the transmission line protection problem.

Assume the impedance of the line is 50 ohm, phase constant is 20 radm and the operating frequency is 700mhz. Electrical power transmission line protection systems. However, nerc protection standards affect and may limit the use of backup protection to ensure that backup protection does not play a role in increasing the extent of outages during system disturbances. Key words switch gear protection, distance relay, line protection, matlabsimulink, impedance. They have replaced the overcurrent protection because of the following reasons. Transmission lines are characterized by a series resistance, inductance, and shunt capacitance per unit length. Gandhi institute of industrial technology presented by sumit kumar padhy regdno1006027 logo btech seminar presentation traveling wave faul location theory traveling wave fault locators make use of the transien signals generated by the fault. For a more detailed discussion on line protection schemes, the reader is referred to the ieee standard c37. Application of current differential protection to tapped. It is also observed the waveforms of voltages and currents by simulating the transmission line with and without faults also.

One is concerned with an adaptive distance relaying algorithm adra designed for transmission line protection. A protection system for high voltage direct current, hvdc, transmission lines is provided. It provides faster protection as compared to overcurrent relay. Paper has made an attempt to obtain travelling waves components in the form of forward wave and backward. Methods for the protection of power transmission lines can be based on various line models ranging from a 50 hz impedance, an lr series circuit, and a. Overload or overcurrent protection owes its application to the fact that the fault current in the event of a short circuit will raise to a value several times that of the maximum load current. Dairyland is committed to the preservation and protection of precious natural resources. The complexity of protecting threeterminal transmission.

Pdf this paper describes an advanced protective relay system for highspeed. Overcurrent protection of transmission and distribution lines overcurrent protection is the simplest and most economical of tl protection schemes. As the length of electrical transmission line is generally long enough and it runs through open atmosphere, the probability of occurring fault in electrical power transmission line is much higher than that of transformers. Transmission line protection using travelling waves generated at the time of fault are.

Sep 10, 2019 electrical power system by jb gupta is very useful for basics ideas of power system and best for competitive exams and topics are covered in sufficient details. Ferc has required that transmission planning processes be open, and transparent, and that. Hon tat hui transmission lines basic theories nusece ee2011 19 6 terminated transmission line note the two coordinate systems and their relation. Jun 30, 2016 ieee guide for protective relay applications to transmission lines abstract. Transmission line protection using travelling waves generated at the time of fault are used as trip signals of a travelling wave relay. A transmission line is a wire with a uniform goemetry along its length. Transmission line distance protection explained in detail. Transmission line protection principles ge grid solutions. Dec 26, 2015 protection of transmission lines distance protection by, rohini haridas assistant professor, dept of electrical engineering, ssgm college of engineering,shegaon 2. Backup protection is achieved by using different protection systems or functions. Line protection must protect for faults on high side of each distribution transformer that is tapped off of line infeed must be considered oklahoma city houston. Pdf lightning protection of compact transmission lines.

Distance relays can be used to protect the transmission lines or power transformers7. Zone 2 is used to cover the rest of the protected line and provide some backup for the remote end bus. Pdf electrical power system by jb gupta pdf download. The advances in the very large scale integrated vlsi technology and software techniques led to the development of. The protective device is energized excited by a short circuit current ik or an overcurrent i which significantly exceeds the operating current in. As the length of electrical transmission line is generally long enough and it runs through open atmosphere, the probability of occurring fault in electrical power transmission line. Protection of transmission lines standard 1 general 1. Apply the sel311c relay for protection, reclosing, monitoring, and control of transmission lines. This chapter presents two examples of the mmbased method used for protection of transmission lines.